HP StoreEver MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and Service Guide (AK378-96059, December 2012)

Table Of Contents
Table 46 Sub-codes for error BD
SolutionCauseMessageSub-code
The Extender robotic cannot
locate its home position within the
master library.
Sensor master home not found.01
Power cycle the master library.
Run the Library Extender cycle
test.
Retry the operation.
The Extender robotic cannot
locate its home position within the
lower library.
Sensor lower home not found.02
Power cycle the lower library.
Run the Library Extender cycle
test.
Retry the operation.
The Extender robotic is stuck in
its home position within the
master library.
Motor blocked in master home
position.
03
Power cycle the master library
and run the Library Extender
cycle test.
Retry the operation. If the motor
is still blocked, remove the
Extender from the libraries, and
then inspect the Extender and
master library for a physical
blockage. Re-install the
Extender.
The Extender robotic is stuck in
its home position within the lower
library.
Motor blocked in lower home
position.
04
Power cycle both libraries and
run the Library Extender cycle
test.
The Extender robotic is stuck
between its two home positions.
Motor blocked between master
and lower home position.
05
Retry the operation. If the motor
is still blocked, remove the
Extender from the libraries, and
The Extender robotic is stuck and
the motor is hot.
Motor blocked and hot.06
then inspect the Extender and
libraries for a physical
blockage. Re-install the
Extender.
Retry the operation.