HP StoreEver MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and Service Guide (AK378-96059, December 2012)

Table Of Contents
Table 50 Warning event codes (continued)
Details and SolutionDescriptionEvent code
Power supply cooling fan failure. Power supply
x fan has failed. Redundancy may be at risk.
(MSL8048 and MSL8096 only)
DD
Verify that the fan for the indicated power
supply is operational and not obstructed.
Upgrade to the latest version of library
firmware.
The subcode indicates which power supply fan
is affected.
If the problem continues, replace the power
supply
Subcode 00: lower power supply
Subcode 01: upper power supply
Power supply x has failed. Redundancy is not
available. (MSL8048 and MSL8096 only)
DE
The subcode indicates which power supply fan
is affected.
Subcode 00: lower power supply
Subcode 01: upper power supply
One of the redundant power supplies has failed.
Redundancy is not available. (MSL4048 only)
DF
Verify that the power supply is correctly inserted
and that the thumbscrews are tightened.
The subcode indicates which power supply fan
is affected.
Power cycle the device.
If the problem continues, contact HP customer
support.
Subcode 00: lower power supply
Subcode 01: upper power supply
Power supply redundancy not available in the
master library.
E9
Verify that the power supplies in the library are
inserted correctly and that the thumbscrews are
adjusted.
Power supply redundancy not available in the
lower library.
EA
Check the AC power cable connections.
NOTE: The MSL2024 does not have a redundant
power supply option.
The port of the FC switch connected to the library
master drive must be in NPIV mode. Verify the FC
switch configuration.
Unable to negotiate for NPIV. Library control path
failover has been disabled.
EC
Common control or data path failover issue.
Failover has been disabled.
ED
A data path failover-related error has occurred.EF
Drive sled missing.F2
Power cycle the device and retry the operation.
Re-seat the tape drive to ensure a good
connection to the device.
MSL8048 and MSL8096: Verify that the drive
is installed in one of the four locations that has
a drive connector.
The master drive must be powered off from the
RMI or OCP to activate control path failover.
The master drive was removed without being
powered off. Library path failover cannot be
performed.
FF
Configuration change events
Table 51 Configuration change events
DescriptionConfiguration eventValue
Drive SCSI ID has changedDrive SCSI changed0x41
Library SCSI ID changed (*)Library SCSI changed0x42
194 Troubleshooting