HP StoreEver MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and Service Guide (AK378-96059, December 2012)

Table Of Contents
Drive Error Code — the current drive error code if the drive is in a failed state. See Drive error
codes (page 188) for a list of drive error codes.
Internal Drive Temperature — internal temperature reported by the drive. The normal
temperature range is provided for reference and varies depending on the type of tape drive.
The tape drive will send out errors if there is any possibility of error due to temperature.
NOTE: The Internal Drive Temperature is not the temperature of the tape path in the drive
nor is this the operating environment temperature.
Cooling Fan Active — On if the cooling fan is on
Drive Activity — the current drive activity
Encryption status — The current status of encryption on the drive.
Port A Status and Port B Status (Fibre Channel tape drives) — current status of the ports
Port A Status (SAS tape drives) — current status of the port
Speed (Fibre Channel and SAS drives) — the current speed setting of the drive port
Port Type (Fibre Channel drives only) — the current setting of the drive port. Direct connected
devices are typically Loop. Devices connected to a switch are typically Fabric.
N-Port ID (Fibre Channel drives only) — Fabric address. Only relevant when in Fabric mode.
ALPA (Fibre Channel drives only) — Loop address. Only relevant when in Loop mode.
Hashed SAS address — A short version of the SAS World Wide Identifier (WWI) that is
generated using a well-defined hash algorithm and is suitable for device identification in most
systems. Some management software may report this value.
Viewing the tape cartridge inventory
The Status: Inventory page provides detailed information about the tapes in the tape drives, with
a summary of tapes in magazine slots.
Remote management interface (RMI) 77