HP StoreEver MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and Service Guide (AK378-96059, December 2012)

Table Of Contents
Figure 81 Configuration: Password page
You may change the:
Password — The password is exactly eight numbers, each from 0 to 9.
Password Time Out — The number of minutes that the current administrator login session will
remain logged in without user interaction.
Setting the date and time
Use the Configuration: Date/Time page to set the date and time.
NOTE: The device does not adjust its time to daylight saving time; the time must be adjusted
manually.
Figure 82 Configuration: Date/Time page
You may change the:
Time — configures the hours, minutes, and seconds for the internal clock. The time is based
on a 24-hour clock, where 1:00 pm is 13:00.
Date — configures the current month, day, and year for the internal clock.
Enable Clock Synchronization When enabled, the device will use the configured Simplified
Network Time Protocol (SNTP) service to obtain the current date and time.
SNTP Server Address the IP address of an SNTP server. The SNTP server may be configured
with either an IPv4 or IPv6 address, or with a host and domain name. If a host and domain
name are entered, the IP address will be resolved from the DNS using that name. The device
will store the resulting address, rather than the name. If the address changes, enter the name
or a new address so the device can find the server again.
Remote management interface (RMI) 91