HP StorageWorks MSL4048 Tape Library firmware release notes Version 6.30 (AK380-96004, July 7, 2008)
• Improved the prompt asking whether to use the configuration settings from the robotics assembly
or library controller when either of these parts are replaced.
• Improved an error message in the Wellness test when an upper corner slot is empty.
• The Library temperature is now reported on LOG SENSE page 0x0D.
• Fixed a case where the Library could not detect when the mailslot was closed very quickly.
Installation
instructions
To upgrade firmware fr om the RMI:
1. Download current firmware using HP Library & Tape Tools or from the HP support website:
h
ttp://www.hp.com/support/storage.
2. Log into the RMI as the administrator user.
3. In the Suppor t: Firmware page, browse to the location of the Library firmware file.
4. Cli ck Updat
e.
To upgrade firmware from the OCP using a USB flash drive:
1. Download current firmware using HP Library & Tape Tools or from the HP support website:
h
ttp://www.hp.com/support/storage.Copythefirmware onto the USB flash drive.
2. Insert the USB flash drive into the USB port on the back of the Library.
3. From the Support menu, select FW Upgrade > By USB.
4. Select the Library as the target for the upgrade, and select the filename of the firm w ar e.
5. Click Up
grade.
6. When th
e upgrade is complete, remove the USB flash drive from the USB port.
Determining current version
To find the version of firmware installed on the Library, see the RMI Support: Firmware screen or the
OCP Info > Identity > Library option.
Firmware Version
Released
Status
6.00
2/20/2008
Active
6.10
6/9/2008
Active
6.30
7/7/2008
Active
Effec
tive date
July 7, 2008