HP StoreEver MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and Service Guide (AK378-96059, December 2012)

Table Of Contents
Regulatory specifications
Table 59 CSA test conditions
Tested condition or valueCharacteristic
Stationary (rack-mount or desk-top)Equipment mobility
Pluggable — Type AConnection to the mains
ContinuousOperating condition
Operator accessibleAccess location
OVC IIOver voltage category (OVC)
-10%, +6%Mains supply tolerance (%) or absolute mains
supply values
NoTested for IT power systems
N/AIT testing, phase-phase voltage (V)
Class IClass of equipment
20 A (branch circuit protection)Considered current rating (A)
PD 2Pollution degree (PD)
IPX0IP protection class
Max 2000Altitude during operation (m)
38Altitude of test laboratory (m)
Max 25 kgMass of equipment (kg)
40 °CManufacturer's Declared Ambient (°C)
NOTE: The CSA test conditions might differ from the product specification limits.
Regulatory specifications 221