HP StorageWorks XPath OS 7.4.X MIB Reference Guide (AA-RVHEC-TE, September 2005)

XPath OS 7.4.x MIB reference guide 23
systemURL
OID 1.3.6.1.3.94.1.2
Description The top-level URL of the system. If systemURL does not exist, the value is an empty string.
The URL format is implementation dependent and can have keywords embedded that are
preceded by a percent sign (for example, %USER).
The following defined keywords are recognized and replaced with data during a launch:
• USER: Replace with a user name.
• PASSWORD: Replace with a password.
• GLOBALID: Replace with a global ID.
• SERIALNO: Replace with a serial number.
Note Provides the virtual IP address of the switch as a URL (for example,
http://10.114.63.74/).
Connectivity unit table
The connectivity unit table contains general information about a system’s units.
connUnitTable
OID 1.3.6.1.3.94.1.6
Description A list of units under a single SNMP agent. The number of entries is given by the value of
uNumber. The value is 1 for a standalone system.
connUnitRevsTable
OID 1.3.6.1.3.94.1.7
Description Table of the revisions supported by connectivity units managed by this agent.
Note The connUnitRevsUnitId displays the WWN value for the local switch.
The connUnitRevsRevId displays the switch type (for example, 38.2) and software version
(for example, 7.4.0).
connUnitEntry
OID 1.3.6.1.3.94.1.6.1
Description A connectivity unit entry containing objects for a particular unit.
Index connUnitId
connUnitId
OID 1.3.6.1.3.94.1.6.1.1
Description The unique identification for this connectivity unit among those within this proxy domain.
The value must be unique within the proxy domain because it is the index variable for
connUnitTable. The value assigned to a given connectivity unit should be persistent
across agent and unit resets. It should be the same as connUnitGlobalId, if
connUnitGlobalId is known and stable.
Note The HP implementation maps the switch WWN to the top eight octets of this variable and
sets the remaining lower eight octets to 0.
To specify a particular instance of any columnar variable in connUnitEntry (such as
connUnitType), specify the instance identifier as a 16-octet value, as follows:
connUnitType.10.0.0.60.69.4.11.19.0.0.0.0.0.0.0.0
The object instance identifier consists of 16 octets, each representing the byte value, from
high byte to low byte, of this 128-bit integer.