Brocade Fabric OS Message Reference Supporting Fabric OS v6.0.0 (53-1000600-01, October 2007)

Fabric OS Message Reference 71
53-1000600-01
Chapter
9
CDR System Messages
CDR-1001
Message <timestamp>, [CDR-1001], <sequence-number>,, ERROR, <system-name>, Port <port
number>
port fault. Please change the SFP or check cable
Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, a faulty cable
between peer ports, or the port speed configuration does not match the capability of the SFP.
Recommended
Action
Verify that you are using compatible SFPs on the peer ports.
Verify that the SFPs have not deteriorated and that the Fibre Channel cable is not faulty. Replace
the SFPs or cable if necessary. If there is a speed configuration mismatch, replace the SFP with a
compatible one or change the configuration.
Severity ERROR
CDR-1002
Message <timestamp>, [CDR-1002], <sequence-number>, FFDC, ERROR, <system-name>, Port
<port number> chip faulted due to internal error.
Probable Cause Internal error.
Recommended
Action
For a bladed system, issue the slotPowerOff and slotPowerOn commands on the blade to recover
the system. For a non-bladed system, perform fastBoot on the switch to recover the system.
Severity ERROR
CDR-1003
Message <timestamp>, [CDR-1003], <sequence-number>, FFDC, CRITICAL, <system-name>, <slot
number>, <chip index> HW ASIC chip error type =0<chip error>
Probable Cause Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may
degrade data traffic.
Recommended
Action
Whenever this error occurs, reboot the system at the next maintenance window. If the problem
persists, replace the blade.