Brocade Fabric OS Message Reference Supporting Fabric OS v6.0.0 (53-1000600-01, October 2007)

82 Fabric OS Message Reference
53-1000600-01
EM-1015
12
EM-1015
Message <timestamp>, [EM-1015], <sequence-number>,, WARNING, <system-name>, Warm recovery
failed (
<Return code>).
Probable Cause Indicates that a problem was discovered when performing consistency checks during a warm boot.
Recommended
Action
Monitor the switch. If the problem persists, a reBoot or power cycle is required to resolve the
problem.
Severity WARNING
EM-1016
Message <timestamp>, [EM-1016], <sequence-number>,, WARNING, <system-name>, Cold recovery
failed (
<Return code>).
Probable Cause Indicates that a problem was discovered when performing consistency checks during a cold boot.
Recommended
Action
Monitor the switch.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
EM-1017
Message <timestamp>, [EM-1017], <sequence-number>,, WARNING, <system-name>, Uncommitted
WWN change detected. Cold reboot required.
Probable Cause Indicates that a user did not commit a changed world-wide name (WWN) value prior executing a
reboot, power cycle, or firmwareDownload operation.
Recommended
Action
Change and commit the new WWN value.
Severity WARNING