Brocade Fabric OS Message Reference Supporting Fabric OS v6.0.0 (53-1000600-01, October 2007)

Fabric OS Message Reference 133
53-1000600-01
FICN-1029
22
Probable Cause An active emulation device received a cancel operation from the FICON channel.
Recommended
Action
If there was an unexpected job failure or IO Error associated with this event, please contact your
vendor's customer support for assistance.
Severity ERROR
FICN-1029
Message <timestamp>, [FICN-1029], <sequence-number>,, ERROR, <system-name>,
HostDiskIng:FICON Selective Reset:Path=<FICON PATH> state=0x<The current
emulation state of the device> LastCmds=0x<The last 4 commands received from the
channel for this device> LastStatus=0x<The last 4 status values presented to the
channel for this device>.
Probable Cause An active disk emulation device received a Selective Reset from the FICON channel.
Recommended
Action
If there was an unexpected job failure or IO Error associated with this event, please contact your
vendor's customer support for assistance.
Severity ERROR
FICN-1030
Message <timestamp>, [FICN-1030], <sequence-number>,, ERROR, <system-name>,
HostDiskIng:FICON Purge received:Path=<FICON PATH>.
Probable Cause An active disk emulation device received a FICON Purge Path from the channel.
Recommended
Action
If there was an unexpected job failure or IO Error associated with this event, please contact your
vendor's customer support for assistance.
Severity ERROR
FICN-1031
Message <timestamp>, [FICN-1031], <sequence-number>,, WARNING, <system-name>,
HostDiskIng:FICON System Reset received on Path=<FICON PATH>.
Probable Cause The FICON channel sent a System Reset to the disk control unit.
Recommended
Action
No action is required. The MVS system was either set to IPL or performing error recovery.
Severity WARNING
FICN-1032
Message <timestamp>, [FICN-1032], <sequence-number>,, INFO, <system-name>,
HostDiskIng:XRC Read Channel Extender Capabilities detected on Path: <FICON PATH>.