FW-1006
29
FW-1006
Message <timestamp>, [FW-1006], <sequence-number>,, WARNING, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the speed of the fan has fallen below the low boundary. Fan problems typically
contribute to temperature problems.
Recommended
Action
Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan
field-replaceable unit (FRU).
Severity WARNING
FW-1007
Message <timestamp>, [FW-1007], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the speed of the fan has risen above the high boundary. Fan problems typically
contribute to temperature problems.
Recommended
Action
Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan
field-replaceable unit (FRU).
Severity WARNING
FW-1008
Message <timestamp>, [FW-1008], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the speed of the fan has changed from a value outside of the acceptable range to a
value within the acceptable range. Fan problems typically contribute to temperature problems.
Recommended
Action
No action is required. Consistently abnormal fan speeds generally indicate that the fan is failing. If
this message occurs repeatedly, replace the fan field-replaceable unit (FRU).
Severity INFO