Brocade Fabric OS Message Reference Supporting Fabric OS v6.0.0 (53-1000600-01, October 2007)

334 Fabric OS Message Reference
53-1000600-01
NS-1004
53
Recommended
Action
To avoid disruption of traffic in the event of an unplanned failover, schedule a firmwareDownload
so that the active and standby CPs have the same firmware version.
Reduce the local device count to follow the capability of the lowest version of firmware.
Severity INFO
NS-1004
Message <timestamp>, [NS-1004], <sequence-number>,, INFO, <system-name>, Number of local
devices <Current local device count>, exceeds the standby can support <Local
device count that standby can support>, can't sync.
Probable Cause Indicates that the name server on the standby CP has lower supported capability than the active CP
due to different firmware versions running on the active and standby CPs. This means that the
active and standby CPs are out of sync. Any execution of the haFailover or firmwareDownload
commands will be disruptive.
Recommended
Action
To avoid disruption of traffic in the event of an unplanned failover, schedule a firmwareDownload
so that the active and standby CPs have the same firmware version.
Reduce the local device count to follow the capability of the lowest version of firmware.
Severity INFO
NS-1005
Message <timestamp>, [NS-1005], <sequence-number>,, WARNING, <system-name>, Zone size of
<Effective Zone Size> has over the supporting limit of <Support Zone Size> for the
remote switch domain ID <Remote Switch Domain ID>.
Probable Cause Indicates that the effective zone size has exceeded the limit that a remote switch can support. The
oversized portion will be truncated.
Recommended
Action
Reduce the zone size to 1024 or lesser, or upgrade the software of the remote switch to support
2048 zones.
Severity WARNING