Brocade Fabric OS Message Reference Supporting Fabric OS v6.0.0 (53-1000600-01, October 2007)

Fabric OS Message Reference 375
53-1000600-01
SEC-1032
66
SEC-1032
Message <timestamp>, [SEC-1032], <sequence-number>,, ERROR, <system-name>, Empty FCS list
is not allowed.
Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1033
Message <timestamp>, [SEC-1033], <sequence-number>,, ERROR, <system-name>, Invalid
character used in member parameter to add switch to SCC policy; command
terminated.
Probable Cause Indicates that a member parameter in the secPolicyAdd command is invalid (e. g., it may include an
invalid character, such as an asterisk). A valid switch identifier (a WWN, a domain ID, or a switch
name) must be provided as a member parameter in the secPolicyAdd command. Only the
secPolicyCreate command supports use of the asterisk for adding switches to policies.
Recommended
Action
Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name)
to add specific switches to the switch connection control (SCC) policy.
Refer to the Fabric OS Command Reference for more information on the secPolicyAdd and
secPolicyCreate commands.
Severity ERROR
SEC-1034
Message <timestamp>, [SEC-1034], <sequence-number>,, ERROR, <system-name>, Invalid member
<policy member>.
Probable Cause Indicates that the input list has an invalid member.
Recommended
Action
Verify the member names, and input the correct information.
Severity ERROR