Brocade Fabric OS Message Reference Supporting Fabric OS v6.0.0 (53-1000600-01, October 2007)

Fabric OS Message Reference 393
53-1000600-01
SEC-1098
66
SEC-1098
Message <timestamp>, [SEC-1098], <sequence-number>,, ERROR, <system-name>, No <active or
defined>
FCS list.
Probable Cause Indicates that the specified policy could not be found.
Recommended
Action
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command
and contact your switch service provider.
Severity ERROR
SEC-1099
Message <timestamp>, [SEC-1099], <sequence-number>,, ERROR, <system-name>, Please enable
your switch before running secModeEnable.
Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1100
Message <timestamp>, [SEC-1100], <sequence-number>,, ERROR, <system-name>, FCS switch
present. Command terminated.
Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR