Brocade Fabric OS Message Reference Supporting Fabric OS v6.0.0 (53-1000600-01, October 2007)

444 Fabric OS Message Reference
53-1000600-01
SULB-1025
69
Severity WARNING
SULB-1025
Message <timestamp>, [SULB-1025], <sequence-number>,, WARNING, <system-name>, The blade
in slot
<Slot number> will reboot with the new firmware.
Probable Cause Indicates that new firmware has been downloaded to the specified AP blade and that the AP blade
will reboot to active it.
Recommended
Action
Wait for the blade to reboot.
Severity WARNING
SULB-1026
Message <timestamp>, [SULB-1026], <sequence-number>, AUDIT, WARNING, <system-name>,
Firmware commit operation started on the blade in slot
<Slot number>.
Probable Cause firmwareCommit has started on the specified blade. The operation may be a normal part of
firmwareDownload, or it may have started to repair the secondary partition of the blade if the
secondary partition is corrupted.
Recommended
Action
No action is required.
Severity WARNING
SULB-1030
Message <timestamp>, [SULB-1030], AUDIT, WARNING, <system-name>, The switch has rebooted
during relocating the internal firmware image.
Probable Cause The error may be caused by an unexpected disruption of the firmwareDownload command, for
example, by powering the switch off and on in the middle of a firmwareDownload. The error may
also be caused by persistent storage hardware failure or by a software error.
Recommended
Action
firmwareDownload will continue after the switch has rebooted. Run the firmwareDownloadStatus
command to monitor progress. If the problem persists, contact your switch service provider.
Severity WARNING
SULB-1031
Message <timestamp>, [SULB-1031], <sequence-number>, AUDIT, WARNING, <system-name>, The
switch is relocating an internal firmware image.