Brocade Fabric OS Message Reference Supporting Fabric OS v6.0.0 (53-1000600-01, October 2007)

458 Fabric OS Message Reference
53-1000600-01
TRCE-1009
73
TRCE-1009
Message <timestamp>, [TRCE-1009], <sequence-number>,, ERROR, <system-name>, Unable to
alert active CP that a dump has occurred.
Probable Cause Indicates that the standby CP is unable to communicate trace information to active CP. This
message is only applicable to the Brocade 24000 and 48000.
Recommended
Action
Run the haShow command to verify that the current CP is standby and the active CP is active.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
TRCE-1010
Message <timestamp>, [TRCE-1010], <sequence-number>,, ERROR, <system-name>, Traced fails
to start
Probable Cause Indicates that the trace daemon (traced), used for transferring trace files, failed to start. The trace
capability within the switch is unaffected. The traced facility is normally restarted automatically by
the system after a brief delay.
Recommended
Action
If the message persists, reboot the CP (dual-CP system) or restart the switch.
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command
and contact your switch service provider.
Severity ERROR
TRCE-1011
Message <timestamp>, [TRCE-1011], <sequence-number>,, INFO, <system-name>, Trace dump
manually transferred to target ' <optional string to indicate which slot the dump
is ftped out.> ': <result>.
Probable Cause Indicates that a manual transfer of trace dump files has occurred.
Recommended
Action
No action is required.
Severity INFO