HP StorageWorks Multi-protocol Router Installation Guide (A7437-96003, September 2005)

Monitoring the MP Router62
Power supply status
Use these steps to display the status of a power supply.
1. Log in to the MP Router as admin.
2. Enter the psshow command.
Example
Possible status values include:
OK—Power supply is present and functioning correctly.
NOT PRESENT—Power supply is not present.
FAIL—Power supply is present but faulty.
Temperature status
Use the tempshow command to display information for each temperature sensor in the MP Router
(the number can vary on different platforms).
1. Log in to the MP Router as admin.
2. Enter the tempshow command.
Example
The possible temperature status values include:
OK—Temperature is within acceptable range.
FAILTemperature is outside of acceptable range (10
o
C to 40
o
C, operating). Damage might
occur.
APswitch:admin> psshow
POWER SUPPLY 1 Serial no:0000101 Part no: 60-0000754-01 Rev: A Status: OK
POWER SUPPLY 2 Serial no:0000096 Part no: 60-0000754-01 Rev: A Status: OK
APswitch:admin>
APswitch:admin> tempshow
Index Status Centigrade Fahrenheit
----------------------------------------------------
1 OK 21 70
2 OK 22 72
3 OK 29 84
4 OK 24 75
5 OK 25 77
APswitch:admin>