HP StorageWorks P9000 Performance Advisor Software v5.3 Install Guide (T1789-96323, August 2011)

prodNameId=3185423&prodTypeId=18964&prodSeriesId=64823&swLang=8&taskId=135&
swEnvOID=181.
This utility supports the upgrade of P9000 Performance Advisor from the source P9000 Perform-
ance Advisor version 3.2 through 3.4 to the target P9000 Performance Advisor v3.5 through
v3.5.2. It also includes the automatic migration of the P9000 Performance Advisor data to the
v3.5 or v3.5.2. For more information on using this utility, see the HP StorageWorks P9000 Per-
formance Advisor Software Release Notes - Database Migration Utility 1.1.0. For document
download location, see Related documentation on page 152.
3. Upgrade from a v3.5 or v3.5.2 to the v4.5, v4.5.1, or v4.6. Complete a set of prerequisites
and proceed with the upgrade process. For more information, see the HP StorageWorks P9000
Performance Advisor Software Installation Guide provided for the v4.5, v4.5.1, or v4.6 respect-
ively. For document download location, see Related documentation on page 152.
4. Upgrade from a v4.5, v4.5.1, or v4.6 to v5.0, v5.1, v5.2, or v5.2.1. Complete a set of pre-
requisites and proceed with the upgrade process. For more information, see the HP StorageWorks
P9000 Performance Advisor Software Installation Guide provided for the v5.0, v5.1, or v5.2
respectively. For document download location, see Related documentation on page 152.
5. Upgrade from a v5.0, v5.1, v5.2, or v5.2.1 to v5.3. Complete the prerequisite on adequate
free disk space and proceed with the upgrade process. For more information, see Using v5.0,
v5.1, v5.2, or v5.2.1 of P9000 Performance Advisor on page 104.
Using a pre-3.5 version of P9000 Performance Advisor
If you are using a pre-3.5 version (v3.2 or later versions), do the following:
1. Upgrade the current version (v3.2 or later versions) to the v3.5 or v3.5.2, which also includes
the migration of the current data using the P9000 Performance Advisor database migration utility
(XPPA_DMU_v1.1.0.zip). To download this utility, see HP Business Support Center: ht-
tp://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareIndex.jsp?lang=en&cc=us&
prodNameId=3185423&prodTypeId=18964&prodSeriesId=64823&swLang=8&taskId=135&
swEnvOID=181.
For more information on using this utility, see the HP StorageWorks P9000 Performance Advisor
Software Release Notes - Database Migration Utility 1.1.0. For document download location,
see Related documentation on page 152.
2. Upgrade from a v3.5 or v3.5.2 to the v4.5, v4.5.1, or v4.6. Complete a set of prerequisites
and proceed with the upgrade process. For more information, see the HP StorageWorks P9000
Performance Advisor Software Installation Guide provided for the v4.5, v4.5.1, or v4.6 respect-
ively. For document download location, see Related documentation on page 152.
3. Upgrade from a v4.5, v4.5.1, or v4.6 to v5.0, v5.1, v5.2, or v5.2.1. Complete a set of pre-
requisites and proceed with the upgrade process. For more information, see the HP StorageWorks
P9000 Performance Advisor Software Installation Guide provided for the v5.0, v5.1, v5.2, or
v5.2.1 respectively. For document download location, see Related documentation on page 152.
4. Upgrade from a v5.0, v5.1, v5.2, or v5.2.1 to v5.3. Complete the prerequisite on adequate
free disk space and proceed with the upgrade process. For more information, see Using v5.0,
v5.1, v5.2, or v5.2.1 of P9000 Performance Advisor on page 104.
Using v3.5.x, v4.0, or v4.1 of P9000 Performance Advisor
If you are using a v3.5, v3.5.2, v4.0, or v4.1, do the following:
1. Upgrade the current version (v3.5, v3.5.2, v4.0, or v4.1) to v4.5, v4.5.1, or v4.6. Complete a
set of prerequisites and proceed with the upgrade process. For more information, see the HP
StorageWorks P9000 Performance Advisor Software Installation Guide provided for the v4.5,
HP StorageWorks P9000 Performance Advisor Software Installation Guide 103