3. If the Oracle directories exist at the following registry key locations, as the Oracle patch installer
queries these registry keys:
HKEY_LOCAL_MACHINE\SOFTWARE\ORACLE is the registry key.
inst_loc: is the name of the registry entry and its value will give the location of the Oracle
inventory.
HKEY_LOCAL_MACHINE\SOFTWARE\ORACLE\KEY_XP_PA_DB is the registry key.
ORACLE_BASE is the name of the registry entry and its value will give the location of the
Oracle base.
ORACLE_HOME is the name of the registry entry and its value will give the location of the
Oracle home.
Error message: The Oracle patch installer for P9000 Performance Advisor Soft-
ware was unable to query the location of Oracle inventory. The installation
wizard will exit now. For more information on troubleshooting Oracle patch in-
stallation issues, see the P9000 Performance Advisor Install Guide available on
Disk 1.
Refer to the description and resolution provided for the previous error message.
Error message: The Oracle patch application library for P9000 Performance
Advisor Software could not be initialized. The installation wizard will exit now.
For more information on troubleshooting Oracle patch installation issues, see
the P9000 Performance Advisor Install Guide available on Disk 1.
The reason might be that Oracle patch application library could not be initialized properly.
Resolution: For further assistance, contact your HP Support representative along with the
opatch<timestamp>.log, <MachineName>_<timestamp>_OraclePatch.log, and
catbundle_WINBUNDLE_PADB_APPLY_<timestamp>.log files.
Error message: One or more services for P9000 Performance Advisor Software
did not stop. The installation wizard will exit now. Rerun the patch installer after
stopping the services from the services control manager. For more information
on the complete list of services to stop, see the P9000 Performance Advisor Install
Guide available on Disk 1.
During the Oracle patch installation process, one or more P9000 services might not stop as expected.
Resolution: Before attempting to re-run the patch installer, stop the following services:
Distributed Transaction Co-ordinator
HP StorageWorks P9000 Performance Advisor Database
HP StorageWorks P9000 Performance Advisor Database Job Scheduler
HP StorageWorks P9000 Performance Advisor Database Listener
HP StorageWorks P9000 Performance Advisor Database VSS Writer
HP StorageWorks P9000 Performance Advisor Monitor
HP StorageWorks P9000 Performance Advisor Security
HP StorageWorks P9000 Performance Advisor Tomcat
Troubleshooting P9000 Performance Advisor installation related issues144