Compaq StorageWorks Getting Started RAID Array 3000 for Microsoft Windows Installation Guide (AA-RACZD-TE, January 2001)

B-6 Getting Started RAID Array 3000 for Microsoft Windows Installation Guide
Compaq Confidential Need to Know Required
Writer: Bob Young Project: Getting Started RAID Array 3000 for Microsoft Windows Installation Guide Comments:
Part Number: AA-RACZD-TE File Name: -appb HSZ22 Host LUN Mapping Procedure.doc Last Saved On: 11/28/00 10:09 AM
And, redundancy groups 47 can be mapped to LUNs 03 on host channel 0
of the top controller as shown in the following tables.
HOST LUN MAPPING HOST LUN MAPPING
Channel 0 Channel 0
Host
LUN
Redundancy
Group
Host
LUN
Redundancy
Group
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
4
5
6
7
-
-
-
-
-
-
-
-
-
-
-
-
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
N: NEXT CH | P: PREV CH | ENTER: SELECT | C: CLEAR | D: DEFAULT | CTRL-Z: EXIT
NOTE: Note that the values of the redundancy group numbers do not exceed the total
number of LUNs – 8 LUNs are mapped using redundancy group numbers 0 – 7. The total
number of LUNs available per controller is eight. In a dual-controller configuration, a
maximum of 16 LUNs is available. The example above pertains to an eight LUN controller
configuration.
The controllers are configured for Active/Active mode.