Compaq StorageWorks RAID Array 3000 Cluster Solutions for Microsoft Windows Installation Guide (EK-NT0EK-IG. C01, January 2001)

4-8 RAID Array 3000 Cluster Solutions for Microsoft Windows Installation Guide
Compaq Confidential Need to Know Required
Writer: Bob Young Project: RAID Array 3000 Cluster Solutions for Microsoft Windows Installation Guide Comments:
Part Number: EK-NT03K-IG. C01 File Name: e-ch4 Software Setup Requirements for Windows NT.doc Last Saved On: 12/4/00 11:25 AM
Installing the HSZDisk Class Driver
Locate the CD-ROM disk labeled RAID Array 3000 Solution Software for
Windows NT, which contains the HSZDisk driver (HSZDisk.sys).
The HSZDisk.sys driver is installed using the HSZ utility. The HSZ utility
installs the driver, checks the event log for miniport and class driver errors,
and also checks the SCSI adapter driver version.
Install the HSZDisk class driver on Host A by performing the following steps:
1. Insert the CD-ROM into your CD-ROM drive.
2. Run File Manager or Windows Explorer.
3. Navigate to the folder: CD\DRIVERS\HZINSTAL\
4. Double-click Setup.
5. Follow the instructions in the setup program to complete the installation.
The installation process copies the driver into the proper subdirectory
and creates the necessary registry entries.
6. Reboot the system.
Verifying Successful HSZDisk Class Driver
Installation
Once the host server is rebooted, verify that the HSZDisk class driver installed
successfully. To verify the HSZDisk installation, follow these steps:
1. Open the Event Viewer from the Administrative Tools group.
2. Locate an information icon in the Event Viewer window with HSZDisk
for the Source.
3. Double-click the HSZDisk entry and an entry detail screen appears.
The message in the detail screen indicates whether the HSZDisk class driver
was successfully installed.