Compaq StorageWorks RAID Array 3000 Cluster Solutions for Microsoft Windows Installation Guide (EK-NT0EK-IG. C01, January 2001)

Software Setup Requirements for a Cluster 4-9
Compaq Confidential Need to Know Required
Writer: Bob Young Project: RAID Array 3000 Cluster Solutions for Microsoft Windows Installation Guide Comments:
Part Number: EK-NT03K-IG. C01 File Name: e-ch4 Software Setup Requirements for Windows NT.doc Last Saved On: 12/4/00 11:25 AM
If any driver installation errors appear in the Event Viewer window, a
connectivity problem may exist on the shared SCSI-bus. HSZDisk will not
load while these problems exist. Check for the following:
Correct termination
Faulty cables or connections
Proper adapter seating in the system backplane
SCSI ID conflicts
Upon successful HSZDisk class driver installation, proceed to the section
below to reassign NTFS partition drive letters or create new drive letters if
none have yet been created.
NTFS Partition Drive Letter Reassignment or
Creation
If preparing Host A and you have not yet created any NTFS partitions on the
RAID subsystem, create them now by running the Disk Administrator utility
on Host A. After doing so, you will have successfully prepared Host A for a
cluster. Return to “Procedures for Preparing Both Host Servers for a Cluster”
to repeat the preceding software setups on Host B.
If preparing Host B, the shared drive letters must be identical on both host
servers in a cluster environment. Reassign the same drive letters to Host B that
you assigned to Host A, using the following the procedures.