Compaq StorageWorks RAID Array 3000 for Windows NT-Alpha Release Notes (AA-RACVC-TE)
StorageWorks RAID Array 3000 for Windows NT – Alpha
4 AA–RACVC–TE
EMU Warning Conditions
Tables 5 and 6 summarize the warning conditions presented by SWCC environmental properties
page and the RA3000 controller shelf fault LED, respectively.
Table 5 SWCC/Caution Icon Warning Conditions
Pedestal UPS Temperature Fan Power Supply
Pedestal
SWCC/Caution Icon ON ON ON ON
Pedestal Expansion
SWCC Caution Icon ON ON ON ON
Controller Shelf
SWCC/Caution Icon ON ON No Caution Icon ON
Expander Shelf
SWCC/Caution Icon N/A No Caution Icon ON (Expansion cabinet
state is abnormal).
ON (Expansion cabinet
state is abnormal).
Table 6 Fault LED Warning Conditions
Pedestal UPS Temperature Fan Power Supply
Pedestal Fault LED ON ON ON ON
Pedestal Expansion
Fault LED ON ON ON ON
Controller Shelf
Controller Shelf LED ON ON No Fault indication ON
Expander Shelf
Controller Shelf LED N/A ON No Fault indication ON
Changing the RAID Array Configuration
NOTE
To safeguard critical data, backup your system using normal
backup procedures before altering device partitions. Do not
alter partitions that contain important data.
When making changes to an existing RAID Array configuration, any existing disk partitions to be
changed (or removed) must first be deleted using the Windows NT Disk Administrator. After they
have been deleted, you may use the StorageWorks RAID Array 3000 Storage Subsystem
Command Console Client to create new virtual disks. (Refer to the Command Console User’s
Guide and on-line help to make the changes).