Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 83
53-1000437-01
EM-1048
11
EM-1048
Message <timestamp>, [EM-1048], <sequence-number>,, INFO, <system-name>, <FRU Id> I2C
access recovered: state <current state>
Probable Cause Indicates that the I2C bus problems have been resolved and I2C access to the field-replaceable
unit (FRU) has become available again.
Recommended
Action
The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is
displayed.
Severity INFO
EM-1049
Message <timestamp>, [EM-1049], <sequence-number>,, INFO, <system-name>, FRU <FRU Id>
insertion detected.
Probable Cause Indicates that a field-replaceable unit (FRU) of the type and location specified by the FRU ID was
detected as having been inserted into the chassis.
Recommended
Action
No action is required.
Severity INFO
EM-1050
Message <timestamp>, [EM-1050], <sequence-number>,, INFO, <system-name>, FRU <FRU Id>
removal detected.
Probable Cause Indicates that a field-replaceable unit (FRU) of the specified type and location was removed from
the chassis.
Recommended
Action
Verify that the FRU was intended to be removed. Replace the FRU as soon as possible.
Severity INFO
EM-1051
Message <timestamp>, [EM-1051], <sequence-number>,, INFO, <system-name>, <FRU Id>:
Inconsistency detected, FRU re-initialized.
Probable Cause Indicates that an inconsistent state was found in the field-replaceable unit (FRU). This occurs if the
state of the FRU was changing during a failover. The FRU is reinitialized and traffic might have been
disrupted.
Recommended
Action
No action is required.