FCR-1055
20
FCR-1055
Message <timestamp>, [FCR-1055], <sequence-number>,, INFO, <system-name>, Switch with
domain ID
<domain ID> does not support backbone to edge imports.
Probable Cause Indicates that a switch that does not support backbone-to-edge routing was detected in the
backbone. Edge-to-edge routing will work, but backbone-to-edge routing might fail.
Recommended
Action
No action is required if backbone to edge routing is not required. Otherwise replace the switch with
one that supports backbone to edge routing.
Severity INFO
FCR-1056
Message <timestamp>, [FCR-1056], <sequence-number>,, INFO, <system-name>, Switch <switch
WWN> with front domain ID <domain ID> does not support backbone to edge imports.
Probable Cause Indicates that a switch that does not support backbone-to-edge routing is running in the MetaSAN.
Recommended
Action
No action is required if backbone-to-edge routing is not needed. Otherwise replace the switch with
one that supports backbone to edge routing.
Severity INFO
FCR-1057
Message <timestamp>, [FCR-1057], <sequence-number>,, ERROR, <system-name>, EX_Port(<port
number>
) incompatible long distance parameters on link.
Probable Cause Indicates that the port, which is configured in long distance mode, has incompatible long distance
parameters.
Recommended
Action
Check the port configuration on both sides of the link using the portCfgShow command.
Investigate the other switch for more details. Run the errShow command on the other switch to
view the error log for additional messages.
Severity ERROR
FCR-1058
Message <timestamp>, [FCR-1058], <sequence-number>,, WARNING, <system-name>, Port <port
number> isolated due to mismatched configuration parameter; <segmentation
reason>.
Probable Cause Indicates that the specified port was isolated after segmentation, which was caused by
mismatched configuration parameters.