Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

154 Fabric OS Message Reference
53-1000437-01
FSSM-1004
26
FSSM-1004
Message <timestamp>, [FSSM-1004], <sequence-number>,, INFO, <system-name>, Incompatible
software version in HA synchronization.
Probable Cause Indicates that the active control processor (CP) and the standby CP in a dual CP system are running
firmware that are incompatible with each other. If the active CP fails, the failover will be disruptive.
In a non-bladed system, this message is logged when the firmware upgrade/downgrade was
invoked. The new firmware version is not compatible with current running version. This cause a
disruptive firmware upgrade/downgrade.
Recommended
Action
For a dual CP system, run the firmwareDownload command to load compatible firmware on the
standby CP. For details on this command, refer to the Fabric OS Command Reference.
Severity INFO