Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

228 Fabric OS Message Reference
53-1000437-01
FW-1428
27
FW-1428
Message <timestamp>, [FW-1428], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor Power supply:
<Number Missing> absent.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet
command.
Recommended
Action
Replace the missing power supply.
Severity WARNING
FW-1429
Message <timestamp>, [FW-1429], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor: Power supplies are not redundant.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the power supplies
are not in the correct slots for redundancy.
Recommended
Action
Rearrange the power supplies so that one is in an odd slot and other in an even slot to make them
redundant.
Severity WARNING
FW-1430
Message <timestamp>, [FW-1430], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor <string>.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty temperature sensors is greater than or equal to the policy set by the switchStatusPolicySet
command. A temperature sensor is faulty when the sensor value is not in the acceptable range or
is faulty.
Recommended
Action
Replace the field-replaceable unit (FRU) with the faulty temperature sensor.
Severity WARNING