Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 229
53-1000437-01
FW-1431
27
FW-1431
Message <timestamp>, [FW-1431], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor Fan:
<Number Bad> bad.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty fans is greater than or equal to the policy set by the switchStatusPolicySet command. A fan is
faulty when sensor value is not in the acceptable range or is faulty.
Recommended
Action
Replace the faulty or deteriorating fan field-replaceable units (FRUs).
Severity WARNING
FW-1432
Message <timestamp>, [FW-1432], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor WWN:
<Number Bad> bad.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty world-wide name (WWN) cards is greater than or equal to the policy set by the
switchStatusPolicySet command.
Recommended
Action
Replace the faulty WWN card.
Severity WARNING
FW-1433
Message <timestamp>, [FW-1433], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor CP: CP non-redundant.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty CPs is greater than or equal to the policy set by the switchStatusPolicySet command. The
CPs are non-redundant.
If you power cycle a Brocade 24000 chassis in dual-domain configuration, and then reset the
micro-switch of the active CP before the heartbeat is up, this will cause both CPs to come up in a
non-redundant state.
Recommended
Action
Run the firmwareShow command to verify that both CPs have compatible firmware levels. Run the
firmwareDownload command to install the same level of firmware to both CPs. Replace any faulty
CPs.
If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was
up on a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to
clear the problem.
Severity WARNING