Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 253
53-1000437-01
HIL-1601
30
HIL-1601
Message <timestamp>, [HIL-1601], <sequence-number>,, ERROR, <system-name>, Using backup
temperature sensor. Service immediately.
Probable Cause Indicates that temperature readings from the primary sensor are out of range.
Recommended
Action
Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating
fan field-replaceable units (FRUs).
Run the tempShow command to verify temperature values. If any sensor is too high, monitor the
switch. Try rebooting or power cycling the switch.
Severity ERROR
HIL-1602
Message <timestamp>, [HIL-1602], <sequence-number>, FFDC, CRITICAL, <system-name>,
Multiple temperature sensors failed. Service immediately.
Probable Cause Indicates that temperature readings from multiple sensors are out of range.
Recommended
Action
Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating
fan field-replaceable units (FRUs).
Run the tempShow command to verify temperature values. If any sensor is too high, monitor the
switch. Try rebooting or power cycling the switch.
Severity CRITICAL