Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

272 Fabric OS Message Reference
53-1000437-01
IPS-1005
38
Probable Cause Indicates that configured Port Mode is different from intended use.
Recommended
Action
Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the
port mode to neutral before attempting to configure the port for a different mode or use.
Severity WARNING
IPS-1005
Message <timestamp>, [IPS-1005], <sequence-number>,, WARNING, <system-name>, Tunnel
Authorization Failure for slot (<slot>) port(ge<port>) tunnel ID(<tunnel number>)
reason (<reason>)
Probable Cause Indicates that tunnel setup failed due to authorization failure from the remote side. Reasons for
such failures could be a WWN Mismatch.
Recommended
Action
Change the tunnel configuration on one side of the tunnel to authorize remote side to setup tunnel.
Severity WARNING
IPS-1006
Message <timestamp>, [IPS-1006], <sequence-number>,, WARNING, <system-name>, Tunnel
Configuration Mismatch for slot (<slot>) port(<port>) tunnel ID(<tunnel number>)
reason (<reason>)
Probable Cause Indicates that tunnel setup failed due to a configuration mismatch between the two ends. Reasons
for such a mismatch could be the Compression, SACK, FastWrite, and TapePipelining setting.
Recommended
Action
Change the tunnel configuration on one side of the tunnel to match that of the other side to setup
tunnel.
Severity WARNING