Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 299
53-1000437-01
Chapter
49
NBFS System Messages
NBFS-1001
Message <timestamp>, [NBFS-1001], <sequence-number>,, INFO, <system-name>, Duplicate
E_Port SCN from port <portnumber> in state <state change name> (<state change
number>)
Probable Cause Indicates that a duplicate E_Port State Change Number was reported. The neighbor finite state
machine (NBFSM) states are as follows:
0 - Down
1 - Init
2 - Database Exchange
3 - Database Acknowledge Wait
4 - Database Wait
5 - Full
Recommended
Action
No action is required.
Severity INFO
NBFS-1002
Message <timestamp>, [NBFS-1002], <sequence-number>, FFDC, ERROR, <system-name>, Wrong
input: <state name> to neighbor FSM, state <current state name>, port <portnumber>
Probable Cause Indicates that the wrong input was sent to the neighbor finite state machine (NBFSM). NBFSM
states are as follows:
0 - Down
1 - Init
2 - Database Exchange
3 - Database Acknowledge Wait
4 - Database Wait
5 - Full
If this error occurs repeatedly, it means the protocol implementation between two connected
switches has problems.
Recommended
Action
Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it
is FULL, then this message can safely be ignored. Otherwise, run the portDisable and portEnable
commands to refresh the port.