Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

324 Fabric OS Message Reference
53-1000437-01
RCS-1004
58
RCS-1004
Message <timestamp>, [RCS-1004], <sequence-number>,, ERROR, <system-name>,
Application(<application name>) not registered.(<error string>)
Probable Cause Indicates that a specified application did not register with RCS.
Recommended
Action
Run the haShow command to view the HA state.
Run the haDisable and the haEnable commands.
Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS
v2.6, v3.1 and greater, v4.1 and greater.
Run the firmwareDownload command to upgrade the firmware for any switches that do not support
RCS.
Severity ERROR
RCS-1005
Message <timestamp>, [RCS-1005], <sequence-number>,, INFO, <system-name>, Phase <RCS
phase>, <Application Name> Application returned <Reject reason>, 0x<Reject code>.
Probable Cause Indicates that a receiving switch is rejecting an RCS phase.
Recommended
Action
If the reject is in ACA phase, wait several minutes and then retry the operation from the sender
switch.
If the reject is in the SFC phase, check if the application license exists for the local domain and if
the application data is compatible.
Severity INFO