Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 353
53-1000437-01
SEC-1080
63
SEC-1080
Message <timestamp>, [SEC-1080], <sequence-number>,, ERROR, <system-name>, Operation
denied. Please, use secModeEnable command.
Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1081
Message <timestamp>, [SEC-1081], <sequence-number>,, ERROR, <system-name>, Entered a name
for a DCC policy ID that was not unique.
Probable Cause Indicates that the device connection control (DCC) policy name given in the secPolicyCreate
command was the same as another DCC policy.
Recommended
Action
Make sure that the DCC policy name has a unique alpha-numeric string, and run the
secPolicyCreate command again.
Severity ERROR
SEC-1082
Message <timestamp>, [SEC-1082], <sequence-number>,, ERROR, <system-name>, Failed to
create
<policy name> policy.
Probable Cause Indicates that the security policy was not created due to faulty input or low resources.
Recommended
Action
Use proper syntax when creating policies. If the security database is too large, you must delete
other members within the database before adding new members to a policy.
Severity ERROR