Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 419
53-1000437-01
Chapter
69
SYSM System Messages
SYSM-1001
Message <timestamp>, [SYSM-1001], <sequence-number>, FFDC, CRITICAL, <system-name>, No
memory.
Probable Cause Indicates that the switch has run out of system memory.
Recommended
Action
Run the memShow command to view the switch memory usage.
Reboot or power cycle the switch.
Run supportFtp as needed) to set up automatic FTP transfers; then run the supportSave command
and contact your switch service provider.
Severity CRITICAL
SYSM-1002
Message <timestamp>, [SYSM-1002], <sequence-number>,, INFO, <system-name>, <number>,
Switch: <Switch number>
Probable Cause Indicates that a user has executed either the switchShutdown or switchReboot command. All
services are brought down for a logical switch.
Recommended
Action
No action is required if the switchShutdown or switchReboot command was executed intentionally.
If the switchShutdown command was run, you must run the switchStart command to restart traffic
on the logical switch.
Severity INFO
SYSM-1003
Message <timestamp>, [SYSM-1003], <sequence-number>,, INFO, <system-name>, <number>,
Switch: <start reason>
Probable Cause Indicates that the user executed the switchStart or switchReboot command. This indicates that all
services are brought back up after a temporary shutdown of that logical switch.
Recommended
Action
No action is required if the switchStart command was executed intentionally. Because reinitializing
a switch is a disruptive operation and can stop I/O traffic, you might have to stop and restart the
traffic during this process.
Severity INFO