Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

420 Fabric OS Message Reference
53-1000437-01
SYSM-1004
69
SYSM-1004
Message <timestamp>, [SYSM-1004], <sequence-number>,, ERROR, <system-name>, Failed to
retrieve current chassis configuration option, ret=
<Unknown>
Probable Cause Indicates that there was a failure to read configuration data from the WWN card.
Recommended
Action
Verify that the world-wide name (WWN) card is present and operational and that the affected
control processor (CP) is properly seated in its slot.
Severity ERROR
SYSM-1005
Message <timestamp>, [SYSM-1005], <sequence-number>, FFDC, CRITICAL, <system-name>, CP
blade in slot
<Slot number> failed to retrieve current chassis type.
Probable Cause Indicates that there was a failure to read the chassis type from the system.
Recommended
Action
Verify that the control processor (CP) blade is operational and is properly seated in its slot.
Severity CRITICAL
SYSM-1006
Message <timestamp>, [SYSM-1006], <sequence-number>, FFDC, CRITICAL, <system-name>, CP
blade in slot
<Slot number> is incompatible with the chassis type.
Probable Cause Indicates that this chassis type is not compatible with the control processor (CP) blade.
Recommended
Action
Use the CP blade on a compatible chassis.
Severity CRITICAL
SYSM-1007
Message <timestamp>, [SYSM-1007], <sequence-number>,, WARNING, <system-name>, PERMITTING
USE OF INCOMPATIBLE CHASSIS FOR CP IN SLOT
<Slot number>. DATA ERRORS MAY
RESULT.
Probable Cause Over-riding the incompatible control processor (CP)/chassis check. For engineering use only
Recommended
Action
Delete the /var/chassis_backplane_override file and reboot the CP.
Severity WARNING