Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

488 Fabric OS Message Reference
53-1000437-01
SULB-1010
83
SULB-1010
Message AUDIT, <timestamp>, [SULB-1010], INFO, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwarecommit failed (status=0x
<error code>).
Probable Cause Indicates that the firmwareCommit failed. The error code provides debugging information. See
Table 11 for more information.
Recommended
Action
If the failure is caused by an inconsistent filesystem, contact your switch service provider.
Severity INFO
SULB-1017
Message AUDIT, <timestamp>, [SULB-1017], ERROR, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwaredownload failed in slot
<Slot number>.
Probable Cause Indicates that firmwareDownload failed in the specified blade. The error may be caused by an
inconsistent AP blade firmware stored on the active CP. It may also caused by an internal Ethernet
issue or by a persistent storage hardware failure.
Recommended
Action
Run the slotShow command. If the blade is in FAULTY state, run the slotPowerOff and slotPowerOn
commands to trigger another firmwareDownload to the blade. If the blade is stuck in LOADING
state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists,
contact your switch service provider.
Severity ERROR
SULB-1018
Message AUDIT, <timestamp>, [SULB-1018], ERROR, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwaredownload timed out in slot
<Slot number>.
Probable Cause The error may be caused by a blade initialization issue after the new firmware is downloaded and
the blade is rebooted. The error may also be caused by an internal Ethernet issue or by a persistent
storage failure.
Recommended
Action
Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and
slotPowerOn commands to trigger another firmwareDownload. If the blade is stuck in LOADING
state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists,
contact your switch service provider.
Severity ERROR
SULB-1020
Message AUDIT, <timestamp>, [SULB-1020], ERROR, FIRMWARE, <event-initiator-details>,
<event-location>, , New firmware failed to boot in slot
<Slot number>.