Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

490 Fabric OS Message Reference
53-1000437-01
SULB-1026
83
Recommended
Action
Run the firmwareShow command to verify the firmware versions. If the blade firmware is the same
as the active CP firmware, firmwareDownload has completed successfully on the blade. However, if
the firmwareCommit operation has been started to repair the secondary partition, at the end of
firmwareCommit, the blade firmware version may still be inconsistent with the active CP firmware.
In that case, firmwareDownload will automatically be restarted on the blade. Run the
firmwareDownloadStatus command to monitor the progress.
Severity WARNING
SULB-1026
Message AUDIT, <timestamp>, [SULB-1026], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmware commit operation started on the blade in slot
<Slot
number>
.
Probable Cause firmwareCommit has started on the specified blade. The operation may be a normal part of
firmwareDownload, or it may have started to repair the secondary partition of the blade if the
secondary partition is corrupted.
Recommended
Action
Wait for the commit operation to complete.
Severity WARNING
SULB-1030
Message AUDIT, <timestamp>, [SULB-1030], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , The switch has rebooted during relocating the internal
firmware image.
Probable Cause The error may be caused by an unexpected disruption of the firmwareDownload command, for
example, by powering the switch off and on in the middle of a firmwareDownload. The error may
also be caused by persistent storage hardware failure or by a software error.
Recommended
Action
firmwareDownload will continue after the switch has rebooted. Run the firmwareDownloadStatus
command to monitor progress. If the problem persists, contact your switch service provider.
Severity WARNING
SULB-1031
Message AUDIT, <timestamp>, [SULB-1031], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , The switch is relocating an internal firmware image.
Probable Cause Indicates that the switch has rebooted with the new firmware and is relocating the AP firmware.
Recommended
Action
Wait for the operation to complete.
Severity WARNING