Brocade Web Tools Administrator's Guide (53-0000194-01, November 2006)

Web Tools Administrator’s Guide 5-11
Publication Number: 53-0000194-01
5
Enabling and Disabling NPIV Ports
N-Port ID Virtualization (NPIV) enables a single Fibre Channel protocol port to appear as multiple,
distinct ports, providing separate port identification within the fabric for each operating system image
behind the port (as if each operating system image has its own unique physical port). NPIV assigns a
different virtual port ID to each Fibre Channel protocol device. NPIV enables you to allocate virtual
addresses without impacting your existing hardware implementation. The virtual port has the same
properties as an N_Port, and is therefore capable of registering with all services of the fabric.
The NPIV license must be installed on a switch before NPIV functionality can be enabled on any port.
To configure NPIV ports, see the Fabric OS Administrators Guide. Web Tools allows you only to
enable or disable the NPIV functionality on a port.
To enable NPIV ports
1. Click a port in the Switch View to launch the Port Management module (see Figure 5-1 on
page 5-2).
2. Click the FC Ports tab.
3. Select the logical port you want to enable in the tree on the left side of the window.
4. Click Enable NPIV.
This option is grayed out if NPIV is already enabled on the port
To disable NPIV ports
1. Click a port in the Switch View to launch the Port Management module (see Figure 5-1 on
page 5-2).
2. Click the FC Ports tab.
3. Select the logical port you want to disable in the tree on the left side of the window.
4. Click Disable NPIV.
This option is grayed out if NPIV is already disabled on the port.
N
ote
NPIV enable/disable is not supported on EX_Ports.