Brocade Web Tools Administrator's Guide (53-0000194-01, November 2006)

19-6 Web Tools Administrator’s Guide
Publication Number: 53-0000194-01
19
Platform-Specific Limitations
Table 19-2 lists Web Tools limitations that are specific to the SilkWorm 24000 director when it is
configured to have two domains.
Windows Operating
Systems
While working on Internet Explorer 6.0, when the user launches the Switch
Explorer it initially does not activate. You will have to click the window once
with the mouse, press the ESC key, the Space Bar, or Enter to activate the
window. This is applicable in all applets launched using IE 6.0.
Workaround: This is not seen while working on Firefox.
Zone Admin The accessibility matrix in the Zone Admin module does not show hosts and
devices zoned by QuickLoop AL_PA as being accessible to each other.
Table 19-1 Web Tools Limitations (Continued)
Area Details
Table 19-2 Platform-Specific Limitations
Area Details
Switch View Neither CP is updated in the Switch View when switch 0 is being
rebooted. The CP data displayed on this Switch View is dependent on
switch 0, and that data is not available when switch 0 is rebooting.
Workaround: Wait until the reboot is finished and Switch View polling
occurs; then, the CPs will be updated properly.
Java Plug-in The Java Plug-in might sometimes have problems focusing on a
particular field in an open applet if you have the same window open for
both logical switches.
Workaround: When this problem occurs, close and relaunch the
affected applet.