HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)
New Diagnostic and System Error Messages
38 Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-CMBISRF, 1
Probable Cause
ASIC central memory SRAMs did not complete the BISR within the timeout
period. This usually indicates an ASIC failure. This message is generated by the
centralmemorytest command, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-CMBISRTO, 1
The ASIC central memory SRAMs did not complete the BISR within the timeout
period. This usually indicates an ASIC failure. This message is generated by the
centralmemorytest command.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-CMBISRF
DIAG-CMBISRTO