HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)
New Diagnostic and System Error Messages
50 Fabric OS 3.1.3a Release Notes
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if
necessary.
If the problem persists:
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-INTNIL, 1
Probable Cause
ASIC failed to get a CMI error (interrupt). This usually indicates an ASIC failure.
This message is generated by the cmitest command, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-INTNIL