Data transmission ranges
Refer to Table 30 and Table 31 for SAN Switches data transmission ranges.
Data transmissions for the 2/8V, 2/16V and 2/16N
Table 30 lists data transmission ranges for different cable types and port speeds.
Data transmissions for the 4/32
Table 31 lists data transmission ranges for different cable types and port speeds.
Table 30 Laser data transmission ranges for the 2/8V, 2/16V and 2/16N
Port speed Cable Short wavelength Long wavelength
1 Gb/sec 50µ 1,640 ft. (500 m.) n/a
1 Gb/sec 62.5µ 984 ft.(300 m.) n/a
1 Gb/sec n/a 6.2 miles (10 km) Optional Long Wave
SFPs are required.
2 Gb/sec 50µ 984 ft.(300 m.) n/a
2 Gb/sec 62.5µ 492 ft.(150 m.) n/a
2 Gb/sec n/a 6.2 miles (10 km) without an HP
Extended Fabrics license; 50 to 100 km
with a HP Extended Fabrics license.
Table 31 Laser data transmission ranges for the 4/32
Port speed Cable size
(microns)
Short wavelength
(SWL)
Long wavelength (LWL) Extended long
wavelength (ELWL)
1 Gbps 50 1,640 feet (500 m) 6.2 miles (10 km) N/A
62.5 984 feet (300 m) 6.2 miles (10 km) N/A
9 N/A 6.2 miles (10 km) 24.8 miles (40 km)