HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 Installation Guide (AA-RVULC-TE, January 2005)

Installing and configuring44
For an HP System/e rack, install two #10-32 x 1/2-inch Phillips pan-head screws
with captive star lock washers and two #10 alignment washers in the upper and
lower hole locations of the right rail. Then install two #10-32 x 1/2-inch Phillips
pan-head screws with captive star lock washers and two #10 alignment washers in
the upper and lower hole locations of the left rail. See Figure 11.
Figure 11 Assembling the outer rails (HP System/e rack)
5. The SAN Switch Rack Mount Kit provides different screw types for securing the inner rails.
Specific switches require a different number of these screws. See Table 8 to determine the
appropriate number of screws.
CAUTION: Do not use any screws other than the ones provided. Use of any longer lengths
can cause damage to internal components.