HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 Installation Guide (AA-RVULC-TE, January 2005)

67SAN Switch 2/8V, 2/16V, 2/16N and 4/32 installation guide
SAN Switch 2/8V, 2/16V and 2/16N LED
patterns
Table 13, Table 14 and Table 15 summarize LED location, color, and recommended action.
System and power LED patterns
The system and power LED patterns are shown in Table 13.
Table 13 System LED patterns during normal operation
LED name,
location
LED color Status of hardware Recommended action
System Status
and Power
Status
At right of
serial port on
bottom
No light Switch is off, boot is not
complete, or boot failed.
Verify that switch is on and has
completed booting.
Steady green Switch is on and power supplies
are functioning properly.
No action required.
Slow-flashing
green
(on 1 second,
off 1 second)
One or both of the following are
true:
One or more environmental
ranges are exceeded.
Error log contains one or more
port diagnostic error messages.
Check environmental
conditions, error log, Port
Status LEDs, transceivers,
cables, and loopback plugs.
Correct error condition.
Clear error log.
Rerun diagnostics to verify fix.
Amber One failed power supply in the
SAN Switch 2/16V
No action required, but failure
of the remaining power supply
will cause the switch to fail.