HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 Installation Guide (AA-RVULC-TE, January 2005)
81SAN Switch 2/8V, 2/16V, 2/16N and 4/32 installation guide
CAUTION: Disassembling any part of the power supply voids the part warranty and
regulatory certifications. There are no user-serviceable parts inside the power supply.
.
Table 21 describes the power supply status LEDs and corrective actions.
3 Power supply 1 status LED
4 Power supply 1
Table 20 SAN Switch 4/32 nonport side LEDs (continued)
Number Description
Table 21 Power supply status LEDs
LED behavior Meaning Correction action
No light The power supply is not receiving
power or is off.
Verify that the power supply is on and
seated and that the power cord is
connected to a functioning power source.
Steady green Power supply is operating normally. No action required.
Steady amber for more
than five seconds
Power supply fault for one of the
following reasons:
• Power cable is disconnected
• Power supply is off
• Power supply has failed
Try the following:
• Check the power cable connection.
• Verify that the power supply is
powered on.
• Replace the power supply.