Limitations Using Mixed OS Versions
Table 2 lists possible limitations when running different OS versions.
Table 2: Limitations Using Mixed OS Versions
Launch Switch Environment Issue and Workaround
Firmware: Earlier than Fabric OS v2.6.2,
v3.1.2, or v4.2.x
Operating System: any supported
operating system (with supported
browser)
Browser: any supported browser (on a
supported operating system)
When trying to access a switch running Fabric OS
v2.6.2, 3.1.2, or 4.2.x from the launch switch, Switch
Explorer displays a null pointer exception, and the
SwitchInfo applet does not display. Switch
Explorer does not work properly with switches
running the latest firmware.
Workaround: Use a launch switch running Fabric OS
v2.6.2, v3.1.2, or v4.2.x or later to access the switch.
Firmware: Earlier than Fabric OS v2.6.2,
v3.1.2, or v4.2.x
Operating System: Any supported
operating system (with supported
browser)
Browser: Any supported browser (on a
supported operating system)
When trying to perform end-to-end monitoring (using
the Advanced Performance Monitoring option) on a
SAN Switch 2/8V, the SAN Switch 2/8V is displayed
as a 16-port switch.
Firmware: Prior to Fabric OS v2.6.2,
3.1.2, or 4.2.x
Operating System: Any supported
operating system (with supported
browser)
Browser: Any supported browser (on a
supported operating system)
When trying to perform Zoning on a SAN Switch
2/8V, the switch is displayed as a 16-port switch.
Workaround: If you are running Secure Fabric OS,
select a switch running Fabric OS v2.6.2, v3.1.2, or
v4.2.x or later as the primary FCS switch. If you are
not running Secure Fabric OS, use a launch switch
running Fabric OS v2.6.2, v3.1.2, or v4.2.x or later