HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N Fabric OS V4.2.X Release Notes

Documentation Updates
18 SAN Switch 2/8V, 2/16V, 2/16N Fabric OS 4.2.x Release Notes
HP StorageWorks SAN Switch 2/8V and 2/16V Installation Guide
On page 32, Table 6: Rack mount kit rails and rail mounting hardware:
Remove the following screw description:
(14) #8-32 x 3/16-inch Phillips pan-head screw with thread lock
Insert the following screw descriptions:
(14) 8-32 x 5/16-inch Phillips pan-head SEMS screw for use with the SAN
Switch 2/8, SAN Switch 2/8V, SAN Switch 2/16, SAN Switch 2/16V and
SAN Switch 2/16N
(14) #8-32 x 3/16-inch Phillips pan-head screw with thread lock for the SAN
Switch 2/32
HP StorageWorks Fabric OS 4.2.x Command Reference Guide
The following commands have been modified:
configure
portCfgGPort
portCfgLongDistance
portCfgislMode
Each change is detailed in the sections that follow.
configure
Change the Domain, R_A_TOV, and E_D_TOV fields as follows:
portCfgLongDistance
Add a Note regarding the portCfgislMode command, as follows:
Note: portCfgislMode and portCfgLongDistance cannot both be enabled at
the same time; otherwise, fabric segmentation occurs.
Field Default Range
Domain 1 Varies
R_A_TOV 10000 E_D_TOV * 2 to 12000
E_D_TOV 2000 1000 to R_A_TOV / 2