HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N Fabric OS V4.2.X Release Notes
Issues and Workarounds
21SAN Switch 2/8V, 2/16V, 2/16N Fabric OS 4.2.x Release Notes
SwitchCfgTrunk leaves ports disabled, if a
long distance port is configured on the switch.
There are two ways to avoid this issue:
■ (Recommended) Use the command port
port cfg trunk port to enable the
trunk for each port.
■ Disable the long distance ports before
issuing switchcfgtrunk.
Immediately after activating SCC policy, the
retrieve sec policy through API fails.
Wait several seconds after activating the new
security policy before issuing a command to
retrieve the security policy.
An error is returned in a large fabric with more
than 26 switches. This occurs when you use the
Fabric Access API to remove multiple FCS
members without first performing a save
operation.
When using the API, perform a save operation
before removing multiple FCS members, if you
have more than 26 switches.
Setting Fcpprobedisable also sets
fanFrameDisable
If you change fcpProbeDisable, make sure
that you clear fcAL.fanFrameDisable to 0.
Web Tools shows incorrect current value on
the smart sfp.
Use the sfpshow command to display the
correct value of current.
Web Tools does not show duplicate entries
contained in Zoning on switch, so you cannot
delete the duplicate entry.
Deleting one member out of the zone list from the
Telnet session may resolve the issue.
Incompatible flow control warning
messages should refer to the area number of
the switchshow when extended Edge PID
(format 2) is set.
In switch PID format 2 (Extended Edge PID
format), this error message is shown as a logical
linear port, which is different from the area
number of switchshow. Add 16 to the logical
linear port number to match the switchshow
area number.
Table 5: Issues and Workarounds
Issue Workaround