Overview
20 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide
Switch Characteristics
The next few sections describe the physical characteristics of the SAN Switch
2/8V, 2/16V and 2/16N and some important requirements for proper operation.
Port Side
You can see the physical differences between the SAN Switch 2/8V and the SAN
Switch 2/16V switches in the following figures. The most noticeable difference is
the number of ports. Figure 1 shows the port side of the SAN Switch 2/8V, and
Figure 2 shows the port side of the SAN Switch 2/16V.
All LEDs are on the port side of the switch: the nonport side is used for serial
number labeling and to allow the free flow of air. The SAN Switch enclosures
have forced-air cooling, with the fans pushing the air from the nonport side of the
chassis through the enclosure, and exhausting to the port side.
A complete description of the locations and interpretations of these LEDs can be
found at “Interpreting LED Activity” on page 59.
Figure 1: Port Side of SAN Switch 2/8V
Table 2 lists the SAN Switch 2/8V port side components.
!
100-240 VAC 1.0A 47-63Hz
IOIOI
0
4
3
7
1
5
2
6
4
0018a
321
Table 2: SAN Switch 2/8V port side components
Number Description
1 AC power receptacle
2 Ethernet port
3 Serial port
4 FC ports (8)