HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Installation Guide, V4.2.X (AA-RVULB-TE, April 2004)

Installing the SAN Switch
37SAN Switch 2/8V, 2/16V and 2/16N Installation Guide
To install the switch in a rack:
1. Check contents of the shipping carton to verify all the required parts and
hardware are available.
2. Choose a mounting location in the rack for the switch.
3. Attach the rear mounting brackets to the rear rack uprights by completing one
of the following steps:
For an HP 10000 series or comparable EIA cabinet, assemble each of the
two brackets with (2) #10-32 x 1/2-inch Phillips pan-head screws with
captive star lock washers and (2) #10 adapter washers as shown in
Figure 5.
Figure 5: Installing the rear mounting brackets (HP 10000 series or comparable EIA
cabinet)
For an HP System/e rack, install each of the two rear mounting brackets
with (2) #10-32 x 1/2-inch Phillips pan-head screws and (2) #10
alignment washers as shown in Figure 6.